Installation steps and precautions for precision security filters

November 18, 2024
1. Installation steps
 
1) Thoroughly clean the filter housing.
 
2) Connect the inlet and outlet of the housing to the filtration system pipeline. Pay attention to the direction when connecting to ensure that the filter element is in the state of water inlet from the outside and water outlet from the inside.
 
3) Open the plastic bag at one end of the filter element opening and check whether the O-ring is intact and in place.
 
4) Wet the O-ring and the filter element seat jack with a suitable wetting agent (such as water).
 
5) Hold the end of the filter element close to the O-ring and vertically insert the filter element socket into the filter element seat jack.
 
6) After all the filter elements are inserted, remove the filter element packaging bag, then buckle the pressure plate to fix it, and then install the upper head.
 
7) Open the bleed valve on the top of the housing.
 
8) Slightly open the inlet valve to allow liquid to enter the housing until the liquid overflows from the bleed valve on the top of the housing, then close the bleed valve.
 
9) Slowly adjust and open the downstream outlet valve until it is fully opened.
 
10) Slowly adjust and open the inlet valve until it is fully opened. At this time, the pressure drop between the upstream and downstream of the filter is 0.02Mpa (the initial pressure drop under the determined flow rate).
 
2. Precautions for use
 
1) Pressure shock should be prevented during operation, and reverse pressure is prohibited.
 
2) When the pressure drop between the upstream and downstream of the filter is greater than 0.3Mpa or the flow rate drops significantly, the filter element should be replaced.
 
3) If the filter is not working temporarily, do not dry the filter element, but soak it in a suitable sterilization solution (or inject such a solution into the shell), and rinse the sterilization solution before reuse.
 
4) If the filter is steam sterilized, the condensed water in the steam pipeline must be drained first, and the steam pressure should not exceed 0.1Mpa. At the same time, the pressure drop between the upstream and downstream of the filter should not exceed 0.015Mpa. If the wet filter element is steam sterilized, the liquid absorbed by the filter element should be drained with clean compressed air before passing the steam, otherwise the filter element will be damaged when the steam is passed.
 
Huatao prefessional in Cartridge Filter Housings Precision Security Filter,Fully automatic candle filter, Spl Double Barrel Mesh Filter,Automatic Filter,Self-cleaing Filter,Bag Filter,Multi Medium Filter,etc.
Contáctenos

Autor:

Ms. Janet Wang

Correo electrónico:

team8@huataogroup.com

Phone/WhatsApp:

++86 17736903537

productos populares
También te puede gustar
Categorías relacionadas

Contactar proveedor

Asunto:
Email:
Mensaje:

Tu mensaje MSS

  • Número de Teléfono:

    +86-0311-80690567

  • Móvil:

    ++86 17736903537

  • Email:

    team8@huataogroup.com

  • Dirección:

    No.298 Zhonghua North Street,Xinhua Dis., Shijiazhuang, Hebei China

  • Follow us:

Hoja informativa

Sign up for industry alerts, our latest news. thoughts, and insights from Huatao Group.

Copyright © 2024 Todos los derechos reservados por Huatao Group.
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Enviar